Categories

Membrane Electrode Assembly (MEA) Activation Procedures

Membrane Electrode Assembly (MEA) Activation Procedures

 

Why is an activation procedure or break-in necessary for a membrane electrode assembly (MEA)? A large reason for performing an activation procedure or break-in is to properly humidify the membrane portion of the MEA that was dried out during the hot press stage of the membrane electrode assembly (MEA) production. MEAs will not work well when they are not fully humidified (see article: Why is Humidity / Moisture Control Important in a Fuel Cell?).

How do I Humidify a Membrane Electrode Assembly (MEA)?

You can re-humidify the MEA by soaking it in deionized water. Be aware that the membrane expands as it is hydrated, so it is possible that you will see some de-lamination of the gas diffusion electrode (GDE) from the membrane if you are using a 5-layer MEA that has the GDE bonded to it. This shouldn't significantly affect performance and you can still install the MEA into your stack or test cell even if portions of it are slightly de-laminated.

The other method to humidify the MEA is to install it in the stack or test cell and then run a break-in process in which it is operated in an air-starved mode periodically. Operate normally (with a suitable load applied) and then turn off the flow on the Air/Oxygen side until the power drops significantly and begins to settle out (around 5 minutes). Then reintroduce the air/oxygen flow until the power increases and stabilizes again. Repeat this as necessary until there are no further performance gains.

What this does is allow for the MEA to produce water (and power) as it consumes the residual oxygen in the system when the flow is removed, but not allow that humidity to escape with the gas flow (as it does during normal operation, to some extent). The hydrophobic surface of the gas diffusion layer/gas diffusion electrode (GDL / GDE) helps to keep the moisture in the membrane without wicking it away - until it's fully saturated, at which point the hydrophobic surface actually helps to push the excess water out of the GDL and into the gas stream without giving it a good place to condense and "flood" the cell.

Membrane Electrode Assembly Activation Procedure

The start-up procedure for a new fuel cell membrane electrode assembly MEA may vary somewhat from application to application. What is important in any research or production environment is to be consistent with the break-in procedure that you use. How the MEA is initially broken in can have long-lasting effects on the ultimate performance of the MEA. Published procedures vary in specifics, but almost all follow a similar sequence:

  1. Initial Start-Up
  2. Load Cycling
  3. Final Performance

The US Fuel Cell Council (USFCC) published a standard for single cell testing that includes specific break-in procedures(beginning on page 15):

  • Fuel: Hydrogen, 1.2 Stoich, 100% RH
  • Oxidant: Air, 2.0 Stoich, 100% RH
  • Temperature (C): 80
  • Pressures (psig): 25

Initial Startup: As required to reach 80C

  1. Cycle Step 1 (Perform Once): Hold 0.6V for 60 mins
  2. Cycling Step 2 (Perform 9 times): Hold 0.7V for 20 mins, than hold 0.5V for 20 mins
  3. Constant Current Operation:Hold at 200 mA/cm2 for 720 mins (12 hrs)

Verify break-in status by repeating the polarization curve sequence three times, or as necessary, to ensure that the cell is broken-in. Remain at each sequence step for 20 minutes. The cell is considered broken in when less than a 5 mV deviation from the previous polarization curve is recorded at 800 mA/cm². A waiting period of 10 minutes should be observed between polarization curves. During this period, return the gas flow rates to the equivalent of 10 stoic at 200 mA/cm² and set the current to 800 mA/cm².


For additional questions or inquiries regarding the activation/break-in procedures of membrane electrode assemblies (MEA) contact us, your membrane electrode assembly experts.

Also, do not forget to check out our standard membrane electrode assemblies here. If you would like a quotation for a custom membrane electrode assembly please contact one of our fuel cell specialists.

Posted by Fuel Cell Store

Products related to this article

Related Articles

Introduction to Fuel Cell Applications

Fuel cells have been researched and developed for use in several applications since the early 1990's. Fuel cells can be used for portable, backup, transportation, and stationary power applications. This article briefly describes some of these uses for fuel cells.

What is a Fuel Cell?

Fuel cells are electrochemical devices that convert chemical energy from the reactants directly into electricity and heat. The device consists of an electrolyte layer in contact with a porous anode and cathode on either side. An illustration of a fuel cell with reactant/product gasses and the ion conduction flow directions through the cell is...

Humidity and Moisture in a PEM Fuel Cell
To properly operate a fuel cell, the proton exchange membranes must stay hydrated. If they are not fully humidified the conductivity decreases and therefore more energy is consumed during the proton transportation phenomenon. If it gets too dry the membrane essentially stops functioning as a proton transporter. Since a hydrogen fuel cell consumes hydrogen and oxygen to generate electricity and water, it would seem that there should be plenty of water around. This creates a problem with potentially flooding the catalyst layer if the excess water is not removed via gas flow to drive the water..
Membrane Comparison Chart - 2024
For PEM fuel cell and electrolyzer applications, a proton exchange membrane is sandwiched between an anode electrode and a cathode electrode. During electrochemical reaction, oxidation reaction at the anode generates protons and electrons; reduction reaction at the cathode combines protons and electrons with oxidants to generate water. To complete the electrochemical reaction, the proton exchange membrane plays a critical role that conducts protons from anode to cathode through the membrane. The proton exchange membrane also performs as a separator for separating anode and cathode reactants..