Why is an activation procedure or break-in necessary for a membrane electrode assembly (MEA)? A large reason for performing an activation procedure or break-in is to properly humidify the membrane portion of the MEA that was dried out during the hot press stage of the membrane electrode assembly (MEA) production. MEAs will not work well when they are not fully humidified (see article: Why is Humidity / Moisture Control Important in a Fuel Cell?).
How do I Humidify a Membrane Electrode Assembly (MEA)?
You can re-humidify the MEA by soaking it in deionized water. ..
If you work with fuel cells, then you are definitely working with polarization curves. The polarization curve does not have a lot of specificity; however, it is one of the most common methods of testing a fuel cell. It also allows an easy comparison to other published polarization curves. The polarization curve displays the voltage output of the fuel cell for a given current density loading...
Showing 1 to 2 of 2 (1 Pages)