The development of high-efficiency Pt and IrO2 electrodes based on the core technology reduces the system production cost and generates hydrogen through the high-yielding rate per input power, and this technology has a long life cycle activating over 20,000 hours for the catalyst materials. The estimated lifetime for the PEM electrolyzer stack components (or individual cells present in the stack hardware), on the other hand,  has a lifetime of approximately 6000 operational hours.  This PEM electrolyzer stack requires distilled water or deionized water for its efficient operation.

Hydrogen generated from the water electrolyzer is used as the energy storage medium for HESS (Hydrogen Energy Storage System). The water electrolyzer can be even powered by renewable energy such as solar, wind-power, tidal, night-time electricity, and surplus power energy. When needed, hydrogen is converted to electricity by the fuel cell.

This product page is only for quotation request purposes.  When you contact, please do specify the kW number in the contact form.

Technical Specifications for 2kW PEM Water Electrolysis System:
  • Stack: LBE-P24SC, 24 cell x 1ea
  • Size (L x W x H): 580 X 374 X 550 mm
  • Power Consumption: < 2 kW
  • Hydrogen Gas Production/h: up to 500 L per hour
  • Oxygen Gas Production/h: up to 250 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 5kW PEM Water Electrolysis System:

  • Stack: LBE-P6C, 6 cell x 1ea
  • Size (L x W x H): 1000 X 550 X 1200 mm
  • Power Consumption: < 5 kW
  • Hydrogen Gas Production/h: up to 1000 L per hour
  • Oxygen Gas Production/h: up to 500 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 10kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 1ea
  • Size (L x W x H): 620 X 910 X 720 mm
  • Power Consumption: < 10 kW
  • Hydrogen Gas Production/h: up to 2000 L per hour
  • Oxygen Gas Production/h: up to 1000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 20kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 2ea
  • Size (L x W x H): 1800 X 550 X 2200 mm
  • Power Consumption: < 20 kW
  • Hydrogen Gas Production/h: up to 4000 L per hour
  • Oxygen Gas Production/h: up to 2000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 40kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 4ea
  • Size (L x W x H): 1500 X 500 X 1800 mm
  • Power Consumption: < 40 kW
  • Hydrogen Gas Production/h: up to 8000 L per hour
  • Oxygen Gas Production/h: up to 4000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 60kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 6ea
  • Size (L x W x H): 1500 X 500 X 1800 mm
  • Power Consumption: < 60 kW
  • Hydrogen Gas Production/h: up to 12000 L per hour
  • Oxygen Gas Production/h: up to 6000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 80kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 8ea
  • Size (L x W x H): 1500 X 500 X 1800 mm
  • Power Consumption: < 80 kW
  • Hydrogen Gas Production/h: up to 19200 L per hour
  • Oxygen Gas Production/h: up to 9600 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 100kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 10ea
  • Size (L x W x H): 2200 X 550 X 1800 mm
  • Power Consumption: < 100 kW
  • Hydrogen Gas Production/h: up to 20000 L per hour
  • Oxygen Gas Production/h: up to 10000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Technical Specifications for 400kW PEM Water Electrolysis System:

  • Stack: LBE-P12C, 12 cell x 40ea
  • Size (L x W x H): 2200 X 550 X 1800 mm
  • Power Consumption: < 400 kW
  • Hydrogen Gas Production/h: up to 80000 L per hour
  • Oxygen Gas Production/h: up to 40000 L per hour
  • Pressure: 0 - 5 bars
  • Temperature: 10 - 60°C
  • Hydrogen Gas Purity: 99.97 - 99.99%
  • Oxygen Gas Purity: 99%
  • Input Voltage: 380 VAC, 3 phase
  • Water source quality: Deionized water or distilled water with resistance of 16-18 MegaOhms

Some of the product specifications may change without any notification as a result of design and material changes at the manufacturer.

Applications:

  • Redundant renewable energy transformation and storage
  • Lab experiment and teaching
  • Laboratory analytic instrument
  • Hydrogen healthy care industrial
  • Hydrogen beauty industrial
  • Fuel for special field
  • Hydrogen supply for fuel cell
  • Other pure H2 application field