The H2 Series hydrogen generation system produces 2 Nm³/hr (76 scf/hr) of ultra-high purity hydrogen gas for applications such as materials processing, power plant cooling, electronics applications, etc. These systems benefit hydrogen users by improving supply reliability and site safety, while also reducing hydrogen storage space.
The generators are modular, field-upgradeable and designed to compete with delivered hydrogen anywhere in the world. A single H6 unit will supply the equivalent of one and one-half jumbo tube trailers every month. Multiple H-systems may be combined for additional capacity at no extra integration cost.
H Series hydrogen generators, combined with Proton Energy's patent-pending StableFlow Continuous Hydrogen Injection Process offer outstanding advantages to hydrogen-cooled electric power plants including reduced windage loss, and improved component life.
Benefits Include
✔ Pure, dry, UHP grade hydrogen - 99.999%
✔ Improved supply reliability by eliminating deliveries
✔ Improved site security
✔ Reduced delivery truck traffic into the site
✔ Reduced paperwork for hydrogen billings
✔ Reduced need to store hydrogen on-site
✔ Lower overall costs
Features
✔ Auto fill water level control
✔ Water monitoring system including purity monitor
✔ Automatic production control
✔ System senses demand and adjusts production rate
✔ Purge airflow monitoring system assures safe operation
✔ Automatic leak detection system
Hydrogen Generator Properties | |
Flow Rate | 2 Nm³/hr at 0°C, 1 bar |
Output Pressure | 15 barg (218 PSIG) / 30 barg option (435 PSIG) |
Purity | 99.9995% |
DI Water Supply | ASTM Type II Deionized Water required, < 1 micro Siemen/cm (>1 megOhm-cm) /// ASTM Type I Deionized Water preferred, < 0.1 micro Siemen/cm (>10 megOhm-cm) |
DI Water Feed Pressure Spec for Auto-Fill | 1.5 to 4 barg (21.8 to 58.0 PSIG) |
Water Consumption Rate | 1.83 L/hr (0.50 gal/hr) |
Power Consumption Rate | 7.3 kWh/Nm³ / 19.2 kWh/100ft³ |
Electrical Supply | 380 to 480 VAC, 3 phase, 50 or 60 Hz |
Ingress Protection Rating | IP66 for electronics compartment. IP43 for fluids compartment; Upgradeable to IP56. |
Max Heat Load | 8.1 kW / 27,368 BTU/hr / (Cooling Requirement - 2.3 tons refrig) |
Operating Temperature | 5°C to 50°C (41°F to 122°F) |
Dimensions | 71” x 32 “ x 75” (180 cm x 81 cm x 191 cm) |
Max Altitude | 2400 m (7874 ft) |
Weight | 1500 lbs (682 kg) |